Sample Type Code Assignment
During an environmental process, many different sample types are established. Within ERPIMS, the Sample Type Code (SACODE) identifies these sample types. A sample will be either a normal environmental sample or one of several quality control sample types. When assigning the SACODE, the purpose of the sample should guide the choice of code.
The following section discusses sample types and SACODEs.
Field Sample Types
Ambient Conditions Blank (AB): An ambient conditions blank, also referred to as a field blank, is ASTM Type II Reagent Grade Water poured at ambient (current) conditions into a sample container at a sampling site. The purpose of this blank is to detect sample contamination introduced during, or as a result of, field sampling activities.
Equipment Blank (EB): An equipment blank, also referred to as an equipment rinsate, is ASTM Type II Reagent Grade Water which is transported to the sampling site, opened and poured over or through the sample collection device, collected in a sample container and sent to the laboratory. The purpose of equipment blanks or rinsates is to measure the cleanliness of the sampling device. There can be more than one equipment blank taken for one site, especially if two different types of equipment are used, such as a bailer and a pump.
Field Duplicate (FD): A field duplicate is a second sample collected as close as possible to the same point in space and time as the sample. There are two separate samples taken from the same source, stored in separate containers and analyzed independently. Field duplicates are useful in documenting the precision of the sampling process and the sample's homogeneity.
Field Replicate (FR): A field replicate, also known as field split, is one sample that is divided and sent to the same laboratory for analysis. Field replicates are used to document the precision of field sampling events and sample homogeneity.
Field Spike (FS): A field spike, or a field matrix spike, is a sample prepared in the field by adding a known amount of analyte(s) to selected samples. They are used to check the effect of field sampling events upon analyte recovery and instrument accuracy. Field spikes are not normally performed due to the possible sources of error which can occur during their preparation.
Field Triplicate (FT): Field Triplicate samples are collected to verify that a Multi Incremental (MI) sample truely represents a decision unit.
Material Blank (MB): Occasionally, samples will be collected on various materials used at or located at a sampling location. This sample is called a material blank. It provides a quality control check on site materials such as cement, bentonite and sand or gravel filter packs.
Material Blank Rinse (RB): Whereas a material blank is an actual sample of a material used or located at a site, a material blank rinse is a rinsate sample collected after the rinsing of a particular site material such as cement, bentonite and sand or gravel filter packs. Like a material blank, it provides a check on the type of material being used at a site.
Matrix Spike (MS): A matrix spike is an aliquot (portion) of sample spiked with a known concentration of target analyte(s). The spiking occurs prior to the sample's preparation and analysis. This spike is used to document the bias introduced due to matrix effects.
Matrix Spike Duplicate (SD): Matrix spike duplicates are intralaboratory split samples spiked with identical concentrations of target analyte(s). Along with the matrix spike, the matrix spike duplicate is used to document the precision and bias of an analytical method in a given sample matrix.
Normal Environmental (N): This is an environmental sample which is a representative sample of any matrix (water, soil, hazardous waste, etc.) collected at a location to make a determination of the location's composition of contamination.
Proficiency Testing Sample (PT): A sample obtained from an approved provider to evaluate the ability of a laboratory to produce an analytical test result meeting the definition of acceptable performance outlined in (AFCEC Reference). The concentration of the analyte in the sample is unknown to the laboratory at the time of analysis. PT samples are used to evaluate whether the laboratory can produce analytical results within specified acceptance limits. Proficiency testing samples are also known as performance evaluation samples or reference samples.
Regulatory Duplicate (RD): Regulatory duplicates, also referred to as referee duplicates or splits, are samples that have been divided into two portions. One of the portions is sent to the referee Quality Assurance (QA) laboratory, if specified by the regulators (state or region), or if a special problem occurs in sample analyses or collection. These duplicates/splits are collected and analyzed in addition to the field duplicates. Regulatory duplicates are used to check precision and accuracy of the analyses being performed.
Trip Blank (TB): Trip blanks are used to detect contamination by volatile organic compounds (VOCs) during sample shipping and handling. Trip blanks are 40 ml VOA vials filled at the laboratory with ASTM Type II Water, transported to the sampling site and returned to the laboratory with volatile samples. These blanks remain unopened until reaching the laboratory where they are only analyzed for volatile organic compounds. One trip blank accompanies each cooler containing volatile samples. A trip blank is used to document contamination traceable to shipping and field handling procedures. This type of blank is useful in documenting contamination of volatile organic samples for both soil and water samples.
Values Used for Entry of Field Quality Control Samples
Sample Type |
LOCID |
SBD & SED |
MATRIX |
SACODE |
LOGCODE |
SMCODE |
SPIKE_ADDED |
EXPECTED |
Ambient blank |
FIELDQC |
0 |
xQ |
AB |
(l) |
G or (sn) |
Null |
0 |
Equipment blank |
FIELDQC |
0 |
xQ |
EB |
(l) |
(sn) |
Null |
0 |
Field duplicate |
[PARENT] |
[PARENT] |
[PARENT] |
FD |
[PARENT] |
[PARENT] |
Null |
Concentration of parent (N) sample |
Field replicate |
[PARENT] |
[PARENT] |
[PARENT] |
FR |
[PARENT] |
[PARENT] |
Null |
Concentration of parent (N) sample |
Field spike |
[PARENT] |
[PARENT] |
[PARENT] |
FS |
[PARENT] |
[PARENT] |
Concentration Spiked |
Spike added + concentration of parent (N) sample |
Field triplicate |
[PARENT] |
[PARENT] |
[PARENT] |
FT |
[PARENT] |
[PARENT] |
Null |
Concentration of parent (N) sample |
Material blank |
(a) |
0 |
(b) |
MB |
(l) |
(s) |
Null |
0 |
Matrix Spike |
[PARENT] |
[PARENT] |
[PARENT] |
MS |
[PARENT] |
[PARENT] |
Concentration Spiked |
Spike added + concentration of parent (N) sample |
Proficiency Testing |
(d) |
0 |
XQ |
PT |
(l) |
NA |
Null |
Manufacturers stated concentration |
Material blank rinse |
(a) |
0 |
(c) |
RB |
(l) |
(s) |
Null |
0 |
Regulatory Duplicate |
[PARENT] |
[PARENT] |
[PARENT] |
RD |
[PARENT] |
[PARENT] |
Null |
Concentration of parent (N) sample |
Matrix Spike Duplicate |
[PARENT] |
[PARENT] |
[PARENT] |
SD |
[PARENT] |
[PARENT] |
Concentration Spiked |
Spike added + concentration of parent (N) sample |
Trip blank |
FIELDQC |
0 |
xQ |
TB |
(l) |
NA |
Null |
0 |
(a) This entry should be the LOCID where the activity occurred.
(b) This entry should be the matrix of the material tested.
(c) This entry should be the matrix of the rinsate tested.
(d) This entry is a place-holder, and can be any normal sample location present in the current project.
[PARENT] The same information as the parent sample.
(l) Value of Logging Company
(S) Value of sampling method employed
(sn) Value of associated normal sample
Laboratory Sample Types
Blank Spike (BS): Blank spikes are used to demonstrate the laboratory process for sample preparation and analysis is in control. Another name for the blank spike is the Laboratory Control Sample (LCS). Both the blank spike and the LCS consist of analyte free matrix that has been spiked with known amounts of specific analytes and are carried through the complete sample preparation and analysis procedure.
Blank Spike Duplicate (BD): The blank spike duplicate is a duplicate sample of the blank spike. This duplicate is taken from the same spiked analyte mix from which the blank spike was made. The blank spike duplicate and the blank spike are designed to check the precision and accuracy of a laboratory's analytical procedures by reporting the percent recovery of a known concentration of an analyte or analytes of interest in the pair of blank spikes.
Continuing Calibration Verification (CV): The Continuing Calibration Verification is a check standard used to determine if the sample analysis is within control limits.
Lab Blank (LB): A lab blank is a water sample of ASTM Type II Water which is designed to detect contamination of the environmental samples introduced by the laboratory. Contamination can occur from laboratory airborne contaminants, instrumentation (GC, GC/MS, etc.) not being clean before sample analysis, improper handling of the sample in the laboratory or other factors. Method blanks and extraction blanks are classified as lab blanks. A method blank is used to determine the existence and magnitude of possible contamination encountered during the preparation and analysis of a sample. The lab blank must be carried through the complete sample preparation and analytical procedure.
Lab Replicate (LR): A lab replicate is a sample split in the laboratory and analyzed twice. These samples are designed to check the precision of the analytical results.
Lab Triplicate (LT): A lab triplicate is a sample split in the laboratory and analyzed three times. These samples are usually associated with Incremental Sampling Methodology (ISM).
Reference Material (RM): This laboratory quality control is usually a water sample of ASTM Type II Water which contains known quantities of target analytes. It is commonly referenced as an instrument's (GC, GC/MS, etc.) check standard and is analyzed before, during and after sample analysis. This reference material, or check standard, is performed in order to ensure that the instrument's calibration is maintained throughout sample analysis. It also is used to re-calibrate an instrument, if necessary, and document the bias of the analytical process being performed.
Reference Material Duplicate (KD): This laboratory quality control is a second analysis of the first successful analysis of the reference material, or check standard. Its purpose is to confirm the results of the first reference material, instrument calibration and analytical method bias.
Values used for Entry of Laboratory Quality Control Samples
Sample Type |
LOCID |
MATRIX |
SACODE |
SBD & SED |
LOGCODE |
SMCODE |
SPIKE_ADDED |
EXPECTED |
Continuing Calibration Verification |
LABQC |
xQ |
CV |
0 |
NA |
NA |
Concentration Spiked |
Spike_added |
Lab blank |
LABQC |
xQ |
LB |
0 |
NA |
NA |
Null |
0 |
Lab replicate |
[PARENT] |
[PARENT] |
LR |
[PARENT] |
[PARENT] |
[PARENT] |
Null |
Concentration of (N) parent sample |
Lab triplicate |
[PARENT] |
[PARENT] |
LT |
[PARENT] |
[PARENT] |
[PARENT] |
Null |
Concentration of (N) parent sample |
Blank spike |
LABQC |
xQ |
BS |
0 |
NA |
NA |
Concentration spiked |
Spike_added |
Blank spike duplicate |
LABQC |
xQ |
BD |
0 |
NA |
NA |
Concentration spiked |
Spike_added |
Reference material |
LABQC |
xQ |
RM |
0 |
NA |
NA |
Concentration spiked |
Spike_added |
Reference material duplicate |
LABQC |
xQ |
KD |
0 |
NA |
NA |
Concentration spiked |
Spike_added |
x Use W for aqueous, S for solid, A for air, G for gaseous or T for tissue quality control samples. Identify the actual matrix of the quality control sample, NOT the matrix of the associated environmental sample.
[PARENT] = the same information as the parent sample.
All photos contained in this online document are linked to full sided images of the imbedded image. Simply click on the image to have a browser view the image in its full size.